EiconCard P92 Installation Guide 21
Cable Construction Information
If you plan to construct your own VHSI cables, be sure to observe the
guidelines given below.
Wire Gauge, Grounding, and Pairing
Use 28 AWG 7-strand wire with 0.020–0.028" insulation.
The chassis must be grounded both by a drain wire and by the
braid; both must be connected to the connector case and shell at
each end of the cable. The braid must be connected through its
full circumference.
Wires identified under the heading “Twisted Pairs” must be
paired. If you do not install twisted pairs correctly, the cable will
not work.
Type of Connectors
The VHSI port accepts a high density 36-pin male cable connector.
The types of connector used on the interface-specific end of the cable
are as follows:
Table 9. Connector Types
Interface Connector
V.35 Type M
V.24 DB25
V.36/RS-449 DB37
EIA-530 DB25
X.21 DB15