Eicon Networks ISDN NT1 Guía de instalación Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
Eiconcard™ Family Installation Guide
page 15
Termination
This section provides instructions to help set up termination
scenarios for installations in Australia and North America.
Termination requirements vary according to the number of ISDN
devices connected to the NT1 and the distance between the ISDN
devices and the NT1.
Terminating resistor
If you purchased the Eiconcard in North America, a 100 ohm
terminating resistor is included. The terminating resistor is
installed by inserting the RJ-45 end of the ISDN cable into the
terminating resistor, and then inserting the terminating resistor
into an ISDN jack.
Terminating a single ISDN device
If the NT1 is connected to a single Eiconcard, then:
If the connection spans 75 meters (250 feet) or more,
set the NT1 to provide 100 ohms of resistance and connect the
terminating resistor. Consult the manual provided with the NT1
for more detailed instructions.
Note: Some NT1s do not support connections over 75 meters.
If the connection spans less than 75 meters (250 feet),
set the NT1 to 50 ohms of resistance and do not connect the
terminating resistor. Consult the manual provided with the NT1
for more detailed instructions.
Terminating multiple ISDN devices
If the NT1 is connected to more than one Eiconcard or other ISDN
device, then follow the instructions below.
If the connection spans 75 meters (250 feet) or more,
then the ISDN device at each end of the connection must be
set to 100 ohm termination. If the Eiconcard is at one end of
the connection, connect the 100 ohm terminating resistor to
the end of the ISDN cable. Consult the manuals provided with
the other ISDN devices and NT1 for detailed instructions.
Note: Some NT1s do not support connections over 75 meters.
If the connection spans less than 75 meters (250 feet),
set the NT1 to 50 ohms of resistance, and do not connect the
terminating resistor. Set the other ISDN devices to no
termination. Consult the manuals provided with the NT1 and
other ISDN devices for more detailed instructions.