Eiconcard™ Family Installation Guide
page 39
Technical specifications
Eiconcard S series
Technical data
Hardware installation
• Automatic configuration of interrupt request level setting and I/O
address
•32-bit I/O access
Performance
• 2 Mbps full duplex per physical VHSI port
• 128 kbps per ISDN BRI port (over the “D” channel or the “B” channels)
Environmental requirements
• Operating temperature: 0°C to 50°C
• Operating humidity: 0 to 90% (non-condensing)
• Barometric operating pressure: 86 to 106 kPascals
• Maximum tolerance in power supply variation: +5% to -5%
Model
CPU/Memory/
Flash
VHSI
Ports
ISDN
BRI
Ports
Connector
Key PCI
Bus
(up to)
Eiconcard S90 25 MHz Motorola
68302 /1 MB RAM / 1
MB Flash
1 N/A 5V 2.1 32 bits
33 MHz
Eiconcard S91 S/T 25 MHz Motorola
68302 / 1 MB RAM / 1
MB Flash
1 1 5V 2.1 32 bits
33 MHz
Eiconcard S91 V2 50 MHz Motorola
855T / 8MB SDRAM
1 1 3.3V or 5V 2.2 32 bits
66 MHz
Eiconcard S92 33 MHz Motorola
68360 / 2 MB RAM / 1
MB FLASH
2 N/A 5V 2.1 32 bits
33 MHz
Eiconcard S94 33 MHz Motorola
68360 / 8 MB RAM / 1
MB FLASH
2 N/A 5V 2.1 32 bits
33 MHz
Eiconcard S94/66 MHz 33 MHz Motorola
68360 / 8 MB RAM / 1
MB FLASH
2 N/A 3.3V or 5V 2.2 64 bits
66 MHz
Eiconcard S94 V2 100 MHz Motorola
852T / 16 MB SDRAM
2 N/A 3.3V or 5V 2.2 64 bits
66 MHz
Eiconcard S94 PCIe 100 MHz Motorola
852T / 16 MB SDRAM
2 N/A PCI Express 1.0a x1
64-0308-09.fm Page 39 Monday, March 15, 2010 3:32 PM