Across the Boards
Communications Device Drivers
Section 3 - General Information
Page 11
cfSOFTWARE Confidential,
2000
Section 3 - General Information
General Device Support
The
Across the Boards
device-drivers that work through 3270 emulation all support the Model-2 devices with
24 lines of 80 columns (1920 byte buffers). Some drivers also support other 3270 Models (3, 4 and 5) and some
support extended attribute bytes (EABs).
Configuration Program - MAINCON
MAINCON.EXE is provided to generate configuration files for the device drivers. This module is menu driven
and fairly self-explanatory.
Some of the device drivers require MAINCON to be run in order to function properly. If the DRIVER does
allow/require configuration, the MAINCON menu will list it.
Keyboard Layout for Manual Mode 3270 Emulation
Select entry A1 of the MAINCON menu to configure keyboard and video monitor usage. The entry allows you
to assign key and Alt_, Ctrl_, and Shift_ key combinations as special 3270 keys (Enter, PF1-24, Clear, up/dn
arrows, etc.). The default keyboard layout is that of Irmas E78.
3270 Controllers
IBM 3274 and 3276
Some of the older IBM 3274 controllers do not transmit the ASCII carat (^ hex 5E) character; they send a dash
(hex 2D) instead. This causes APPX applications to get an error #221 (DUPLICATE CHARACTER...) in
PPX_MESSAGE at CONNECT time. To correct his problem use the MAINCON configuration program:
-select A1 (Video Monitor Mode ...)
-set the Keyboard Language field to 9
-save the configuration via F10
-when using APPX, be certain that the configuration file produced, MAINCFG.VDT, is either in
the current disk directory or in the directory pointed to by PPX_PATH.
As of 02/09/93, Configuration Support D Version 65.1 is the current microcode for the 3274.
IBM 3174
For 3174 Asynchronous Emulation Adapters (AEAs), see Section 5.1 Protocol Converter Special
Considerations.
To use the IBM 3174 controller or any 3174 look-alike, you must customize the controller as follows: