6.15 MAINCON Panel D2
IBM 3101
Configuration filename: MAINCFG.PRX
Used by cf Device Drivers:
#
Name Description
9 CFXPROX, CFXPROI, CFXPRON,
HYDPROX, HYDPROI, HYDPRON
IBM 3101 Protocol Converter
For DOS, CFXPROX is the direct to COMM port driver, CFXPROI is the INT 14h driver, and CFXPRON in
the NASI driver. The correct driver is automatically loaded as defined in MAINCFG.POR. For Windows and
OS/2, CFXPROX supports all functions.
__________________
ACROSS-THE-BOARDS(r) Config
__________________
Page 1 of 6
---- Protocol Converter (IBM 3101) -----
Auto-wrap? (0=No, 1=Yes)................ 0
Reset needed after BELL? (0=No, 1=Yes).. 0
XON/XOFF (in hex) FF if no XON/XOFF..... 11 13
Hardware flow control (0/1/2)........... 0
Flicker check time (in 100ths second)... 0
Keystroke delay (in milliseconds)....... 0
COMM port (1 - 15)...................... 1
Line Speed/Parity/Data bits/Stop bits... 1200 E 7 1
Attributes (0 or 1)..................... 0
Half Duplex (0 or 1).................... 0
Print routing (in hex).................. 00
If the protocol converter assumes that the 3101 automatically does a carriage
return at the end of a line, enter 1.
F10: write config to disk Esc: Exit PgDn: config 3101 key values
1. Autowrap
When set to ‘1’, this switch causes the cursor to wrap to the beginning of the next line automatically when
the last position in a line is written to by the protocol converter.
2. BEL reset
If the protocol converter locks the keyboard after sending a BELL character, setting this switch to ‘1’ will
cause a RESET key sequence to be sent after receiving a BELL. The RESET key is defined in the 3101
KEY TABLE.
3. XON
If the protocol converter uses XON/XOFF pacing, specify the XON character used in this field. Use 0FFh
for no XON/XOFF processing. 11h is the standard XON.
4. XOFF
If the protocol converter uses XON/XOFF pacing, specify the XOFF character used in this field. Use 0FFh
for no XON/XOFF processing. 13h is the standard XOFF.