Across the Boards
Communications Device Drivers
Section 6 - MAINCON Driver Configuration
Page 231
cfSOFTWARE Confidential,
2000
6.8 MAINCON Panel B6
Pathway Remote
Configuration filename: MAINCFG.PTH
Used by cf Device Drivers:
#
Name Description
11 CFXPATH, CFXPAT4, OLDPATH, OLDPAT4 Pathway/ICOT Remote
__________________
ACROSS-THE-BOARDS(r) Config
__________________
------------ Pathway Remote ------------
Logical unit (LU)....................... 0
Pathway interrupt number (in hex)....... 60
Enter LU number to connect to (0 to 31 if bisync, 2 to 255 if SNA).
F10: write config to disk Esc: Exit
1. Logical Unit
The logical unit number to access. This must match a configured LU number in the emulation software.
For BISYNC, 0 through 31 are valid, and for SNA, 2 through 255 are valid.
2. API Interrupt Number
This number for Pathway defaults to decimal 96 (hex 60). If pathway emulation software has been
configured for some other interrupt number, then that new number must be indicated here.
Comentarios a estos manuales